== Planned Organization of Areas ==
 
== Planned Organization of Areas ==
 +
[[File:MakersLocal256_MarkIII_Labled.jpg]]
 
Total Area of 4012 sqft, building is 70'x38'.
 
Total Area of 4012 sqft, building is 70'x38'.
  

Revision as of 17:31, 19 October 2011

Mailing Address

Calendar

Planned Organization of Areas

MakersLocal256 MarkIII Labled.jpg Total Area of 4012 sqft, building is 70'x38'.

Lobby with front door

Dimensions: 6'9"x20'

Large Office

Dimensions: 15'6"x13'

Kitchen

Dimensions: 10'8"x13'3"

Kitchen Hallway

Kitchen Closet

Dimensions: 6'9"xX'

2 Bathrooms

Main Garage Area

Dimensions: 53'4"x24'

Proposed:

  • Tool Floor
  • Woodworking Area
  • Storage

Garage Loft

L-shaped section that sits atop office areas and runs along West and North walls of building.

West Run Above Warehouse

Dimensions: 14' wide

Proposed:

  • Material Storage - Recommend this be done for small/lightweight stock to simplify material delivery from upper floor storage to work areas on Main Garage Area floor.

North Run Above Offices

Dimensions: 15'6" wide

Proposed:

  • Art Space
  • Electronics Lab
  • Audio/Visual Lab - Else, soundproof a lower floor room.
  • Storage?
  • Social Space?

Half-Completed Room Under Loft

Dimensions: 11'x15'

Space Under Loft

Dimensions: Under West run of Garage Loft. 14' wide and ends at South wall of Half-Completed Room Under Loft.

Lit Driveway Area

Garbage Area

East Lawn

Dimensions: All lawn East of shop and South of the building's North Wall, not including parking; ~35'x30'

Proposed:

  • Garden/Grill/Outdoor Hangout Space

North Lawn

Dimensions: All lawn North of shop, not including parking; ~30'x75'

Proposed:

  • Garden/Grill/Outdoor Hangout Space

Parking

Proposed: On the property, we can have 10 spaces for large cars in loose formation.

  • ~20'x66' gravel lot for regular parking on North edge of property along Stevens Ave. (reference SouthEast corner of the lot is at the telephone pole in the NorthEast corner of the property). This will grant 5 large car plots in a regular loose formation. The limiting factors are the neighbor's mailbox being on the West edge of the lot and the curvature of the turn for the Stevens-Schiffman intersection East of the lot.
  • ~20'x20' space for regular parking on Eastern edge of property along Schiffman St. There is a fire hydrant East of the NorthEast telephone pole. To provide fire clearances, the ~20'x20' space will need to be directly North of the driveway. This puts it 15' South of the fire hydrant. This grants 2 large car plots in a regular loose formation.
  • 3 regular loose formation spaces on the driveway. To allow for an area for members to work outside, cars ought to park at the end of the driveway. Only issue is that garage door and lit driveway work area is blocked from street access.
  • Additional parking possible by parking on the roadside bordering the city-owned land North of the shop across Stevens Ave., parking on Stevens Ave. under the highway bridge and parallel parking on the neighbors.

MakersGoogleMap4.png

NOTE: Interior parts of the lawn cannot be used as parking due to lack of space for access.

Issues with the Landlord

Insurance Info

TODO

Please refer to We Need To Move Page

Climate Control

Cooling & Heating

The following is cooled and heated by an (assumed) 18,000 BTU window A/C unit running off of 220V (predicted to be able to cool/heat 750-1000 sqft):

  • Large Office - A/C unit stationed here.

The following areas are cooled/heated by proxy to the above room:

  • Lobby With Front Door
  • Kitchen
  • Kitchen Closet
  • Kitchen Hallway
  • 2 Bathrooms

All other indoor areas are uncooled/unheated, they are ventilated by a 700 Watt wall vent fan.

Notes: Shop Heating & Cooling

Weatherization

Per landlord, the following areas have walls insulated to R-19 (needs verification):

  • Large Office - Two tall single-glazed slit windows (~4'x1'), one facing East and the other facing North. One single-glazed observation window (~3'x5') facing to Main Garage Area. Wall aperture (~1.5'x2') for A/C unit facing East.
  • Lobby With Front Door - One tall single-glazed slit window (~4'x1') facing North, one outside entrance (~7'x4') facing North, weatherstripped.
  • Kitchen
  • Kitchen Closet
  • Kitchen Hallway
  • 2 Bathrooms

All other indoor areas uninsulated. Recommend weatherization of door between Kitchen Hallway and Main Garage Area for insulation and soundproofing. Will prevent heat transfer between conditioned and unconditioned areas.

Security

ADT Alarm System

Cameras

Access Control

Safety

See Facilities Committee Page/Priority List under 'Shop Safety'.

Fire/Disaster/Hazards

  • Fire Mitigations - ?
  • Disaster Preparedness - ?
  • Radon
    • As of 5/3/11, from discussion with the board, Facilities Director and concerned parties, the following course of action is recommended:
      1. Purchase a radon test kit and perform a self-test. A test is cheap; up to $15 for a test kit and 3 days to 12 months of testing (per here).
      2. Ask for a radon clause on the next lease term for our safety and coverage (none on current lease term). We had one for the 203 Brown St lease stating the building tested as radon safe. A similar one is recommended that would state landlord responsibility for testing and, if needed, mitigations.
      3. Take action as needed based on the radon test results.
    • The basis of the action is that radon, as a radioactive gas, poses a long-term health risk and that Madison County has a high potential of having dangerous levels of radon (more information from here). To detail, per Madison County Radon Test Results; in the zip code for 414 Stevens Ave 35801, 2225 homes have tested with an average radon level of 6.05 picoCuries of radiation per litre of air (pCi/l). Above 4 pCi/l is the recommended action level by EPA and AL Department of Health. 35.78% of the homes tested are over this limit. Note that building construction affects radon levels. Therefore, a radon test is needed to accurately confirm elevated levels of radon.
    • Notes: Details on Madison County radon levels and testing and mitigation resources here.
  • General Hazard Mitigations - ?

Chemical & Material

Tools

Members

See New Member Shop Walkthrough.

Maintenance & Sanitation

See Facilities_Director#Duties

Utilities

Water

Electricity

Cable/Internet/Phone

Operating Costs

  • Predicted $1110 avg/mo
  • Observed: Pending

Notes